Model
HUD-E808-90

Item specifics

Internal Size (L×W×H)
600*450*400mm
Equipment Material
Both inside & outside shell adopt P.V.C rigid plastic board
Temperature Range
Room temperature ~ 55℃
Temperature Fluctuations
≤±0.5℃
Temperature Uniformity
≤±2℃
Temperature Precision
±1℃
Spraying method
Continuous and Periodic spray type
Test Chamber Temperature
Salt Spray Method (NSS ACSS)35±1℃
Brine Temperature
35℃±1℃

Review

Description

Video

Application

The salt spray test chamber is mainly suitable for the surface treatment of various materials, including coatings, electroplating, organic and inorganic coatings, extreme treatments, anti-rust oils and other anti-corrosion treatments to test the corrosion resistance of their products.

Features

1. Durable 8 mm PVC construction, anti-corrosion and easy to clean.

2. Reservoirs with mixing system on stand.

3. Separate heating system apart from salt testing chamber to ensure accurate result and protect circuit.

4. Exposure zone lined with corrosion-resistant PVC sheets.

5. Clear cover allows viewing of test conditions.

6. Peaked cover prevents dripping of condensation onto samples.

7. Water seal and water level protection system.

8. Heated humidifying tower with air relief valve, adjustable tower tip to orient salt fog.

9. Automatic DI water fills to humidifying tower.

10. Digital temperature control.

11. Integral over-protection on heaters.

12. Low water cut-off protection on humidifying tower.

Main Parameters 

Internal Size (W*D*H)

900*600*500mm

External Size (W*D*H)

1410*880*1280mm

Equipment Material

P.V.C rigid plastic plate, thickness 8mm

Sample tray

Diameter 10mm glass fiber rod, anti-rust

V-shape plastic steel to make sure sample in 15~30 degree inclined

Temperature Range

Room temperature ~ 55℃

Temperature Fluctuations

≤±0.5℃

Temperature Uniformity

≤±2℃

Temperature Precision

±1℃

Spraying method

Continuous and Periodic spray type

Test Chamber Temperature

Salt Spray Method (NSS ACSS)35±1℃
Corrosion-resistant Testing Method (CASS) 50±1℃

Saturated air Barrel Temperature

Salt Spray Method (NSS ACSS)47±1℃
Corrosion-resistant Testing Method (CASS) 63±1℃

Brine Temperature

35℃±1℃

Spray Quantity

1.0~2.0 ml / 80cm2 / hr

PH value

Salt Spray Method (NSS ACSS6.5~7.2)
Corrosion-resistant Testing Method(CASS)3.0~3.2

Lab Volume

270L

Brine Tank Capacity

25L

Multiple Safety Protection Devices

Current discharge protection, over pressure protection, over temperature protection, over load fuse protection

Accessories

Testing Salt/ Measuring tank/Nozzle Equipment x 1 set

Internal Size (W*D*H)

900*600*500mm

Test criteria

ASTM B117-08, ISO 9227