Three Zones Thermal Shock Test Chamber 丨 High-Low Temperature Test Equipment
Three Zones Thermal Shock Test Chamber 丨 High-Low Temperature Test Equipment
Model
HUD-E703 Thermal Shock Test Chamber

Item specifics

Product name
Thermal Shock Test Chamber
Temperature range
-40 ~ +80℃
High temperature chamber pre-heating range
60 ~ 100℃
Heating speed
+60→+100℃ about 10 minutes
Cooling speed
Ambient →-65℃ about 65 minutes
Temperature deviation
±3℃

Review

Description

APPLICATION

Thermal shock testing subjects a product to alternating extremes of high and low temperatures in order to observe changes in the product’s characteristics and failure occurrences caused by different materials and thermal expansion.

FEATURES
1 Perfect appearance and easy to operate.
2 Imported LCD English microcomputer temperature controller, with high memory capacity, can save 100 programs, max 9999 cycles, each cycle max time 999hrs.
3 High temperature chamber and low temperature chamber, control automatically, stay and switch time adjustable.
4 Perfect protection alarm functions: short-circuits, Leakage, over temperature of work chamber; compressor over pressure, over load, short water…
5 Control interface will display alarm reason and provide check methods, machine has emergency stop button.
6 Cold and hot shock temperature recover within1 minute, which complies with MTL, IEC, JIS, GJB and other international standards. 
MAIN PARAMETERS 

Test method

Pneumatic operated door switch 3 chambers

Inner dimension (W*D*H)

500*450*450mm

External dimension (W*D*H)

1380*1370*1980mm

Temperature range

-40 ~ +80℃

High temperature chamber pre-heating range

60 ~ 100℃

Heating speed

+60→+100℃ about 10 minutes

Low temperature chamber pre-cooling range

-65 ~ 0

Cooling speed

Ambient →-65℃ about 65 minutes

Temperature deviation

±3℃

Thermal recovery time

Thermal recovery time

External material

Antirust processing cold-rolled steel sheet

Internal material

SUS#304 stainless steel

Thermal insulation material

Polyurethane foam and fiberglass

Coolant

R404A / R23

Cooling method

Air cooling

Pressure

0.2 - 0.5Mpa

Power supply

Three phase, 380V, 50Hz


DETAILS

High temperature chamber:

1, Including three parts: heater, draught fan and air duct valve

2, Draught fan cyclically stirs hot air through heater

3, The basket with testing product drive to high temperature range when doing high temperature impact test.

 

Low temperature chamber:

1, Including four parts: evaporator, energy storage piece, draught fan and air duct valve

2, Draught fan cyclically stirs cold air through evaporator and energy storage piece.

3, The basket with testing product drive to low temperature range when doing low temperature impact test.

 

 

Drive device:

Pneumatic cylinder: drive basket with testing product to high and low temperature chamber

Air compressor: Provide the compressed air for driving pneumatic door (supplied by buyer)

 

Refrigerating device:

Cooling system: complex overlapping efficient cryogenic loop system

Compressor: Bock compressor

Refrigerant: environmental protection refrigerant R23/R404A

Condensation: Stainless steel welded plate heat exchanger

 

Controller:

Operate interface: PLC controller, touch screen

Program memory capacity: 100 groups

Setting range: Time: 1 minute ~ 99 hour 59 minute, cycles: 1~ 9999cycles

Resolution: temperature: 0.01 ℃

Input: T thermocouple

Control method: PID auto calculation control

 

Additional functions:

Timer, over temperature and power failure protection, alarm, record test curve, emergency stop, display test time

Standard configuration: indication lamp of test chamber, time meter, test hole for wire routing, 6pcs castor, 4pcs adjust wheel.

 

Safety device:

Power overload protection                                 

Leakage protection

Control circuit overload protection

Short-circuit protection

Compressor overload protection

Ground protection

Over temperature protection

Audible and visual alarm