Walk In Test Chamber Environment chamber test
- Model
- HUD-E705-8
Item specifics
- Product Name
- Walk In Test Chamber
- interior walls
- stainless steel 304
- exterior walls
- cold rolled stell plate with baking finish
- humidity range
- 40% to 98% RH
Review
Description
Walk In Test Chamber
Product introduction:
Walk in test chamber is large testing equipment of constant temperature and humidity test chamber series, according to the requirements of users can change the chamber size and function;walk in test chamber is typically used for testing or storing products that require a large capacity chamber.
Specifications:Walk in test chamber
specification | CTHR |
---|---|
temperature range | -50C to +100C |
humidity range | 40% to 98% RH |
dimension (internal) (w x d x h) | 1500 X 1500 X 3000 mm |
dimension (external) (w x d x h) | 2850 X 1700 X 3200 mm |
ramp | variable, temp. 0~5c / min & humidity 0~5%/min in average, no load |
accuracy | temp. ±1c, humidity ±2.5%rh |
interior walls | stainless steel 304 |
exterior walls | cold rolled stell plate with baking finish |
temperature & humidity measurement and controller | 32 bit control and monitoring system.interface facility with rs232programmable temp. humid. controller |
viewing window | multi pane glass window size |
port holes | 50 mm diameter for wire routing |
power supply requirement | three phase, ac380 v ± 10 %, 50 hz |
sound pressure level | <72DB (A) |
condenser cooling | water cooled |
Other Environmental Chamber Series
Constant Temperature And Humidity Test Chamber | ||||
---|---|---|---|---|
Internal dimension(W*D*H) | External dimension(W*D*H) | Temperature Range | Humidity Range | |
Environmental Chamber | 400*500*500mm | 600*1280*1380mm | -40~+150℃ | 20~98%R.H. (Refer Image below) |
Stability Chamber | 400*500*500mm | 600*1280*1380mm | -70~+150℃ | 20~98%R.H. (Refer Image below) |
Climatic Test Chamber | 500*500*600mm | 700*1080*1480mm | -40~+150℃ | 20~98%R.H. (Refer Image below) |
Temperature Test Chamber | 500*500*600mm | 700*1080*1480mm | -70~+150℃ | 20~98%R.H. (Refer Image below) |
Humidity Test Chamber | 500*600*750mm | 700*1180*1630mm | -40~+150℃ | 20~98%R.H. (Refer Image below) |
Climate Test Chamber | 500*600*750mm | 700*1180*1630mm | -70~+150℃ | 20~98%R.H. (Refer Image below) |
Environmental Test Chamber | 600*800*850mm | 800*1380*1730mm | -40~+150℃ | 20~98%R.H. (Refer Image below) |
Temperature Test Equipment | 600*800*850mm | 800*1380*1730mm | -70~+150℃ | 20~98%R.H. (Refer Image below) |
Temperature Controlled Chamber | 1000*800*1000mm | 1500*1180*1900mm | -40~+150℃ | 20~98%R.H. (Refer Image below) |
Humidity Controlled Chamber | 1000*800*1000mm | 1500*1180*1900mm | -70~+150℃ | 20~98%R.H. (Refer Image below) |
Stability Test Chamber | 1000*1000*1000mm | 1500*1380*1900mm | -40~+150℃ | 20~98%R.H. (Refer Image below) |
Climatic Chamber | 1000*1000*1000mm | 1500*1380*1900mm | -70~+150℃ | 20~98%R.H. (Refer Image below) |
Walk In Test Chamber | 1500*1500*3000mm | 2850*1700*3200mm | -50~+100℃ | 40~98%R.H. |
Electrical Panel Controller Feature
1.all power connectors, protection devices power control logic built in the control panel integrated to the chamber
2.all electrical cables tagged with id number
3.all electrical function circuit equipped with its own safety device that shuts down the relevant circuit or the entire test chamber if a faulty develops
4.all electrical systems comply with recognized technical regulation as well as with the accident prevention regulations.
Walk in test chamber meet following standards:
GB/BT2423.2-89 high temperature test method
GB2423.1-89 test A: low temperature test method
GJB150.4-1986 test at low temperature
IEC60068-2-1 low temperature test method
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature
Walk in test chamber meet following standards:
Temperature Humidity Range: